Test Code LEGRP Legionella species, Molecular Detection, PCR, Varies
Additional Codes
Torrance Memorial Laboratories Test Code: 137855241
Reporting Name
Legionella PCRUseful For
Sensitive and rapid diagnosis of pneumonia caused by Legionella species
The assay is not recommended as a test of cure because bacteria nucleic acids may persist after successful treatment.
Method Name
Rapid Polymerase Chain Reaction (PCR)
Performing Laboratory
Mayo Clinic Laboratories in RochesterSpecimen Type
VariesNecessary Information
Specimen source is required.
Specimen Required
The high sensitivity of amplification by polymerase chain reaction requires the specimen to be processed in an environment in which contamination of the specimen by Legionella DNA is unlikely.
Specimen Type: Lower respiratory
Sources: Bronchoalveolar lavage, bronchial aspirate/brushing/lavage/washing, tracheal/endotracheal secretions/aspirate, sputum
Container/Tube: Sterile container
Specimen Volume: 1 mL
Specimen Type: Fresh tissue or biopsy
Sources: Lung, pleura, heart valve, pericardium
Container/Tube: Sterile container
Specimen Volume: Entire collection or 5 mm(3) - approximately the size of a pencil eraser
Collection Instructions: Aseptically collect a 1 to 2 cm(3) piece of tissue whenever possible
Specimen type: Fluid
Sources: Pericardial, pleural, chest, chest tube drainage, thoracentesis, empyema
Container/Tube: Sterile container
Specimen Volume: 1 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Varies | Refrigerated (preferred) | 7 days | |
Frozen | 7 days |
Reject Due To
Tissue in formalin, formaldehyde, or acetone Formalin-fixed paraffin-embedded (FFPE) block |
Reject |
Reference Values
Not applicable
Day(s) Performed
Monday through Sunday
Report Available
3 daysCPT Code Information
87801
LOINC Code Information
Test ID | Test Order Name | Order LOINC Value |
---|---|---|
LEGRP | Legionella PCR | 5020-3 |
Result ID | Test Result Name | Result LOINC Value |
---|---|---|
SRC57 | Specimen Source | 31208-2 |
29515 | Legionella PCR, Result | 5020-3 |
Test Classification
This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.Forms
If not ordering electronically, complete, print, and send a Microbiology Test Request (T244) with the specimen.