Sign in →

Test Code FCQBA Circulating Immune Complex, C1q Binding

Important Note

TML Outreach Instruction:  Perform expedite processing

Additional Codes

Torrance Memorial Laboratories Test Code:  278446985

Reporting Name

CIC, C1q Binding

Method Name

Semi-Quantitative Enzyme-Linked Immunosorbent Assay

Performing Laboratory

ARUP Laboratories

Specimen Type

Serum


Specimen Required


Collection Container/Tube: Red Top or SST

Submission Container/Tube: Plastic vial

Specimen Volume: 1 mL

 

Collection Instructions: Draw blood in a plain, red-top tube(s). (Serum gel tube is acceptable.) Allow complete clotting of red blood cells (up to 1 hour), then separate serum from cells withing 30 minutes and freeze immediately. Send 1 mL of serum frozen in a plastic vial.

 

Note: Critical frozen. Separate specimens must be submitted when multiple tests are ordered.

 


Specimen Stability Information

Specimen Type Temperature Time Special Container
Serum Frozen 14 days

Reject Due To

Gross hemolysis: reject
Thawing: Warm reject; Cold reject
Other: Non-frozen specimen
   

Reference Values

0.0-3.9 ug Eq/mL

Day(s) Performed

Saturday, Monday, and Thursday

Report Available

4 to 15 days

CPT Code Information

86332

LOINC Code Information

Test ID Test Order Name Order LOINC Value
FCQBA CIC, C1q Binding 27831-7

 

Result ID Test Result Name Result LOINC Value
Z2636 CIC, C1q Binding 27831-7