Test Code 68429322 Anti Scl 70 Ab
Peforming Laboratory
Torrance Memorial Laboratories
Specimen Requirements
Specimen Type: Serum
Container/Tube: Serum Gel
Allow to sit 30 minutes prior to spinning. Spin within 2 hours of collection.
Specimen Transport Temperature
Refrigerated
Storage Temp Stability
Room Temperature: 8 hours
Refrigerated: 14 days
Methodology
Fluoroenzyme Immunoassay (EliA™)
Reference Range
<7 = Negative
7-10 = Equivocal
>10 = Positive
Testing performed on the Phadia 250 analyzer using Fluorescence Enzyme Immunoassay technology.
*Note: Reference ranges provided on this web site are for guidance only, and may not reflect the most recent changes. Refer to laboratory reports for current data.
Day(s) Test Set Up/TAT
Performed:
Monday, Wednesday
Not available STAT
TAT:
1-5 days
Aliases
JO1
CPT Code
86235 x1