Test Code 62871507 Uric Acid
Performing Laboratory
Torrance Memorial Laboratories
Specimen Requirements
Submit only 1 of the following specimens:
Hospital Preferred Specimen Type: Plasma
Container/Tube: Lithium heparin gel
Outreach Preferred Specimen Type: Serum
Container/Tube: Serum gel
Spin Instructions:
Serum gel: Allow to sit for 30 minutes prior to spinning. Spin within 2 hours of collection.
Heparin plasma: Spin within 45 minutes of
collection.
Also acceptable: Red top tube
Specimen Transport Temperature
Ambient
Storage Temp Stability:
Room Temperature: 3 days
Refrigerated Temperature: 7 days
Methodology
Spectrophotometry
Reference Range
Males: 3.5 - 7.2 mg/dL
Females: 2.6 - 6.0 mg/dL
Day(s) Test Set Up/TAT
Performed:
Daily
Available STAT
TAT:
STAT: < 1 hr
Routine: < 4 hrs
Aliases
.
CPT Code
84550