Test Code 62871386 Rubella IgG (Immune status)
Performing Laboratory
Torrance Memorial Laboratories
Specimen Requirements
Submit the following specimens:
Specimen Type: Serum
Container/Tube: Serum gel
Spin Instructions:
Serum gel: Allow to sit for 30 minutes prior to spinning. Spin within 2 hours of collection.
Specimen Transport Temperature
Refirgerated
Storage Temp Stability:
Refrigerated Temperature: 9 days
Methodology
Chemiluminescent Immunoassay Performed on the Diasorin Liaison ® XL
Reference Range
See table below
*Note: Reference ranges provided on this web site are for guidance only, and may not reflect the most recent changes. Refer to laboratory reports for current data.
Index Value |
Result |
Interpretation |
< 0.90 Index |
Negative |
Sample is considered negative for IgG antibodies to rubella virus. A negative result presumes that immunity has not been acquired. If exposure to rubella virus is suspected despite a negative finding, a second specimen should be collected and tested one or two weeks later. Seroconversion from a negative specimen to a positive specimen is evidence of either recent infection, response to vaccination, or administration of immunoglobulins. |
≥ 0.90 Index and < 1.0 Index |
Equivocal |
The equivocal sample should be re-tested. In case the result remains in this range after repeat testing, a second sample should be collected. |
≥ 1.00 Index |
Positive |
Sample is considered positive for IgG antibodies to rubella virus |
Day(s) Test Set up/TAT
Performed:
Monday - Friday
Not available STAT
TAT: 1 - 3 days
Aliases
.
CPT Code
86762