Test Code 62870886 C4 Complement

Specimen Requirements

Submit the following specimen:

Specimen Type: Serum
Container/Tube: Serum gel
Additional Instructions: Allow to sit for 30 minutes prior to spinning.  Spin within 2 hours of collection.

 

Also acceptable:  Red Top Tube

Specimen Transport Temperature

Refrigerated

 

Storage Temp Stability
Refrigerated 7 days

Methodology

Immunoturbidimetric

Reference Range

1 to 14 years

Male:      14 to 44 mg/dL

Female:  13 to 46 mg/dL

 

>14 to 80 years

Male:      15 to 53 mg/dL

Female:  15 to 57 mg/dL

Day(s) Test Set Up/TAT

Performed:

Daily 

Routine TAT < 4 hours

 

Not available STAT

 

Aliases

Complement C4

C4

 

CPT Code

86160