Sign in →

Test Code 580232873 Mononucleosis Screen with reflex to Epstein-Barr Virus Panel if Negative

Performing Laboratory

Torrance Memorial Laboratories (Mononucleosis Screen)

Mayo Medical Laboratories (Epstein-Barr Virus Panel), if needed

Specimen Requirements

Submit the following specimens:
 

Specimen Type: Serum

Container/Tube: Red top or serum gel

Collection Instructions: Allow to sit for 30 minutes prior to spinning.  Spin within 2 hours of collection.

Specimen Transport Temperature

Ambient/Refrigerated OK

 

Storage Temp Stability:
Ambient: 24 hours
Refrigerated:  7 days

Methodology

Immunoassay

Reference Range

Negative 

 

Interpretive data (new as of 6/2/16)

Interpretative Guidelines for Acceava Mono Cassette

A patient may have a negative mono test in the presence of hematological and clinical evidence of disease due to the following:
1. Some patients take longer than 3 months to develop heterophile antibodies detected in this assay.
2. Some individuals will not produce measureable heterophile antibodies.
3. Infection may not be due to Epstein Barr.

Heterophile antibody production can also be found in patients with leukemia, cytomegalovirus, Burkett’s lymphoma, Rheumatoid Arthritis, adenovirus, viral hepatitis and Toxoplasma gondii.
 

(If negative, Epstein-Barr Virus Panel will be sent to Mayo (additional charge applies; see that test listing for CPT code)

Day(s) Test Set up/TAT

Performed:

Daily

Available STAT

TAT:

STAT: <1 hr

Routine: < 4 hours

Aliases

Mono

CPT Code

86308

 

*Additional codes/fees may apply*