Test Code 3886638641 Anti-Xa Low Molecular Weight Heparin, prophylaxis
Performing Laboratory
Torrance Memorial Laboratories
Specimen Requirements
Submit the following specimen:
Specimen Type: Platelet-poor plasma. Frozen samples must be double spun
Container/Tube: Light-blue top (3.2% sodium citrate)
Minimum volume: 1 mL plasma
Rejection: Clotted, wrong anticoagulant, under or over-filled, gross hemolysis, gross lipemia, gross icteric
Specimen Transport Temperature
Ambient
Storage Temp Stability:
Ambient: 2 hours
Frozen: 14 days
Methodology
1-stage chromogenic assay. Performed on Instrumentation Laboratory ACL TOP 500
Reference Range
0.2 to 0.4 IU/mL
Interpretive Data:
Heparin Anti-Xa assay is used to measure heparin concentrations in patients receiving unfractionated heparin or low-molecular-weight heparin.
Very low endogenous antithrombin III (AT III) levels might result in spuriously-low results.
Antibodies to bovine factor X or AT III can interfere with assay (very rare). This is not a test for the presence of inhibitors directed against factor X.
Day(s) Test Set Up/TAT
Performed:
Daily
Available STAT
TAT:
STAT: < 1 hr
Routine: < 4 hrs
Aliases
.
CPT Code
85520