Test Code 230539699 Vitamin D 25-Hydroxy
Performing Laboratory
Torrance Memorial Laboratories
Specimen Requirements
Submit only 1 of the following specimens:
Hospital Preferred Specimen Type: Plasma
Container/Tube: Lithium heparin gel
Outreach Preferred Specimen Type: Serum
Container/Tube: Serum gel
Spin Instructions:
Serum gel: Allow to sit for 30 minutes prior to spinning. Spin within 2 hours of collection.
Heparin plasma: Spin within 45 minutes of collection.
Also acceptable: Red top tube
Specimen Transport Temperature
Ambient
Storage Temp Stability:
Room Temperature: 72 hours
Refrigerated Temperature: 7 days
Methodology
Immunoassay
Reference Range
30.00 - 100.00 ng/mL
See interpretive data
Interpretive data:
Vitamin D Status Range
Deficiency <20 ng/mL
Insufficiency 20-30 ng/mL
Sufficiency 30-100 ng/mL
Toxicity >100 ng/mL
Since there is no national standard for Vitamin D testing, results from different methodologies should not be interchanged. The results for this test were generated using the Abbott Alinity Immunoassay test effective June 22, 2021.
Day(s) Test Set Up/TAT
Performed:
Daily
Available STAT
TAT:
STAT: < 1 hr
Routine: < 4 hrs
Aliases
Vitamin D Total, Vitamin D (D2 plus 3)
CPT Code
82306