Test Code 146535629 Corn IgE

Performing Laboratory

Torrance Memorial Laboratories

Specimen Requirements

Submit the following specimen:

 

Specimen Type: Serum

 

Container/Tube: Serum gel

 

Also acceptable: Red Top Tube

 

Additional Instructions: 

1.  Allow to sit for 30 minutes prior to spinning.  

2.  Spin within 2 hours of collection.

 

Unacceptable specimen type:  Grossly hemolyzed or lipemic

Specimen Transport Temperature

Transport Temperature

Refrigerated

 

Specimen Stability

Room Temperature:  8 hours

 

Refrigerated: 7 days

Methodology

ImmunoCAP Fluorescence Enzyme Immunoassay

Reference Range

REFERENCE INTERVAL: Allergen, Interpretation

Less than 0.10 kU/L.......Class 0......No significant level detected
0.10-0.34 kU/L............Class 0/1....Clinical relevance undetermined
0.35-0.70 kU/L............Class 1......Low
0.71-3.50 kU/L............Class 2......Moderate
3.51-17.50 kU/L...........Class 3......High
17.51-50.00 kU/L..........Class 4......Very High
50.01-100.00 kU/L.........Class 5......Very High
Greater than 100.00 kU/L..Class 6......Very High

Allergen results of 0.10-0.34 kU/L are intended for specialist use as the clinical relevance is undetermined. Even though increasing ranges are reflective of increasing concentrations of allergen-specific IgE, these concentrations may not correlate with the degree of clinical response or skin testing results when challenged with a specific allergen. The correlation of allergy laboratory results with clinical history and in vivo reactivity to specific allergens is essential. A negative test may not rule out clinical allergy or even anaphylaxis.

Day(s) Test Set Up/TAT

Performed:

TBD

 

Available STAT:

No

 

TAT: 

TBD

CPT Code

86003 x1

Aliases

.